HS-50 Fiber Optic Gyroscope

  • Single 5V power supply, extremely low power consumption
  • Innovative structural design, with a height of only 32mm
  • Excellent startup performance, can reach the nominal specifications upon power on, without the need for preheating
  • Excellent full temperature performance, with an accuracy better than 1 °/h in a variable temperature environment of 1 ℃/min
  • Interference fringe recognition technology, supporting full dynamic range cold start
  • The impact resistance can reach 1000g
  • High reliability

HS-50 is a fully solid-state miniaturized digital closed-loop single axis fiber optic gyroscope that integrates optics, mechanics, and electronics. Based on the SAGNAC principle, it consists of an SLD light source, fiber coupler, photodetector, integrated optical phase modulator, fiber sensing ring, circuit, and structural body. It follows the classic design concept of traditional fiber optic gyroscope and adopts mature fiber optic gyroscope manufacturing technology. This gyroscope sensor has outstanding advantages such as small size, light weight, low power consumption, fast start-up, simple interface, and easy use. It is an ideal choice for low precision angular rate sensors in the control field and  widely used in various inertial measurement and control fields of national economic construction and defense equipment construction.

 

Specifications

Environmental Specifications
Operating Temperature -45~+70
Storage temperature -55~+80
Vibration 6.06g , 20Hz-2000Hz (Operating)
Impact 1000g,0.7ms
Mean time between failures 5000h
Electrical Characteristics
Power supply +5V
Steady state power consumption ≤2.5W
Steady state power consumption at full temperature ≤4W
Start instantaneous power consumption ≤4W
Overall dimensions 50mmx50mmx32mm
Weight 120g
Output RS422
Technical Specifications
Startup time 5s
Zero bias stability (25) 0.2°/h
Zero bias stability (1/min environmental temperature variation) 1°/h
Zero bias repeatability 0.2°/h
Random walk coefficient 0.03*/√h
Scale factor nonlinearity ≤50ppm
Scale factor repeatability ≤50ppm
Scale factor asymmetry ≤50ppm
Dynamic range ±1000°/s
Band width (-3db) >200Hz

 

Applications

  • Optical pod/flight control platform/guidance head
  • Strapdown inertial navigation/measurement system
  • Optical/photographic instruments
  • Platform stabilization device
  • Inertial measuring instruments

 

Drawing

FOG dimension